Straightpoint Radiolink Plus-ATEX-Hazardous Area

ATEX/IECEx dynamometer load cell approved to Ex ia II C T4 Ga for use in zone 0,1 & 2 hazardous environments (gas).

Upper and lower shackles are not included.

 SW-HHP-ATEX Hand held display is included.

An intrinsically safe load cell, this new version of the bestselling Radiolink plus is capable of both weighing and dynamic load monitoring in hazardous environments such as on and offshore oil, gas and chemical industries in zones classified 0,1 & 2.
Available from stock in capacities from 1t to 300t, constructed from high-quality aircraft grade aluminium and featuring an advanced internal design structure.

This internal design structure not only provides the product with an unrivalled strength to weight ratio but also allows the use of a separate internal sealed enclosure providing the load cell’s electronic components with IP67/NEMA6 environmental protection even with the battery cover plate missing, making this industry leading dynamometer even more suitable for use in the harshest environments.
Featuring industry leading wireless technology and range, the versatile Radiolink plus – ATEX is supplied with an update rate of 3Hz and can be easily configured to run at industry leading speeds of up to 200Hz. Data is transmitted wirelessly utilizing the latest in IEEE 802.15.4 (2.4 GHz) technology providing safe, high integrity, error free transmission of both static weight and dynamic load to an ATEX/IECEx approved wireless handheld controller, the SW-HHP-ATEX
The Radiolink plus-ATEX utilizes easily sourced Energizer® Ultimate Lithium AA Batteries and features advanced circuitry designed to protect the loadcell from damage if the batteries are incorrectly installed. This advanced circuitry extends battery life and the use of easily sourced batteries eliminates issues associated with rechargeable battery pack charging, failure and replacement.
It is easy to see why globally the Radiolink plus-ATEX is the number one choice for weighing and dynamic load monitoring in hazardous applications.

  • Approved for use in hazardous zones 2, 1 and O
  • Proprietary 2.4 GHz Wireless
  • Industry Leading Wireless Range
  • Error Free Data Transmission
  • Unrivalled Resolution
  • Environmentally Sealed
  • Internal Antennae
  • Compact Size
  • Remote On-Off
  • Lightweight
  • Peak Hold
  • Unmatched Battery Life
  • Design validated by F.E.A

Please contact us for capacities greater than 50 tons.

ATEX/IECEx dynamometer load cell approved to Ex ia II C T4 Ga for use in zone 0,1 & 2 hazardous environments (gas).

Upper and lower shackles are not included.

 SW-HHP-ATEX Hand held display is included.

An intrinsically safe load cell, this new version of the bestselling Radiolink plus is capable of both weighing and dynamic load monitoring in hazardous environments such as on and offshore oil, gas and chemical industries in zones classified 0,1 & 2.
Available from stock in capacities from 1t to 300t, constructed from high-quality aircraft grade aluminium and featuring an advanced internal design structure.

This internal design structure not only provides the product with an unrivalled strength to weight ratio but also allows the use of a separate internal sealed enclosure providing the load cell’s electronic components with IP67/NEMA6 environmental protection even with the battery cover plate missing, making this industry leading dynamometer even more suitable for use in the harshest environments.
Featuring industry leading wireless technology and range, the versatile Radiolink plus – ATEX is supplied with an update rate of 3Hz and can be easily configured to run at industry leading speeds of up to 200Hz. Data is transmitted wirelessly utilizing the latest in IEEE 802.15.4 (2.4 GHz) technology providing safe, high integrity, error free transmission of both static weight and dynamic load to an ATEX/IECEx approved wireless handheld controller, the SW-HHP-ATEX
The Radiolink plus-ATEX utilizes easily sourced Energizer® Ultimate Lithium AA Batteries and features advanced circuitry designed to protect the loadcell from damage if the batteries are incorrectly installed. This advanced circuitry extends battery life and the use of easily sourced batteries eliminates issues associated with rechargeable battery pack charging, failure and replacement.
It is easy to see why globally the Radiolink plus-ATEX is the number one choice for weighing and dynamic load monitoring in hazardous applications.

  • Approved for use in hazardous zones 2, 1 and O
  • Proprietary 2.4 GHz Wireless
  • Industry Leading Wireless Range
  • Error Free Data Transmission
  • Unrivalled Resolution
  • Environmentally Sealed
  • Internal Antennae
  • Compact Size
  • Remote On-Off
  • Lightweight
  • Peak Hold
  • Unmatched Battery Life
  • Design validated by F.E.A

Please contact us for capacities greater than 50 tons.

$11,585.50 $10,674.30 $10,173.65 $9,246.30 $8,596.05 $8,290.05 $8,060.55

MODEL:

DOCUMENTATION -